ImmunoStrip® for Bt-Cry1Da
This ImmunoStrip® test is intended for seed and leaf quality purposes to determine the presence or absence of Bt-Cry1Da in transgenic corn grain, leaf, and single seed.
ImmunoStrip® tests require no expertise to run. Results are obtained in as little as a few minutes making them perfect for use in the field. The ImmunoStrip must be used with tap water for compositie seed or single seed testing. The ImmunoStrip must be used with 1X SEB4 sample extraction buffer for leaf testing.
Click here for other product documents such as the User Guide or Validation Report.
Included in STX Item:
- ImmunoStrips®
- User Guide
Required but Not Included:
- Tap water
- SEB4 Extraction Buffer Powder
- Micropipette tips
- Graduated cylinder
- Balance 1-500 gram
- Scissors and pen
- Timer
- Grinding equipment
- Sample tube rack
- 1.5 mL microcentrifuge tubes (ACC 00340)
- Mesh sample bags (ACC 00930) and rubber mallet (optional)
For a full list of included items, including sizes, please see the Content List.
Validation Report Summary
Test Format: ImmunoStrip® Lateral Flow Device (LFD) |
Full Validation Report |
Diagnostic Sensitivity and Specificity |
---|
Total Samples: 2880 Correct Diagnoses: 2872 Number of Operators: 9 Number of Production Lots: 3 Percent: 99.7% |
Proteins Detected | |
---|---|
Bt-Cry1Da |
Cross-reactions | |
---|---|
None Known |
For a list of validated hosts, please see the Full Validation Report.
Additional Documents | ||
---|---|---|
![]() |
![]() |
![]() |
![]() |
![]() |